A clinical study utilizing a 1064 nm Q-switched Nd:YAG laser demonstrated significant facial rejuvenation with a high safety profile. In a trial involving women with mild to moderate photodamage, 60% of participants achieved at least a one-point improvement on the Glogau scale after a series of four treatments. Crucially, the procedure was reported as painless and resulted in no adverse side effects.
The 1064 nm Q-switched Nd:YAG laser offers a viable, non-invasive solution for early-to-moderate skin aging. It effectively reverses visible signs of photodamage—such as wrinkles and laxity—without the pain or recovery time associated with more aggressive ablative therapies.
Analyzing the Treatment Protocol
Patient Demographics and Condition
The study focused on a cohort of ten women exhibiting signs of mild to moderate photodamage.
Specific clinical presentations included telangiectasias (spider veins), solar keratosis, skin sagging, and general dryness. Prior to the intervention, these patients were assessed as Glogau type II (wrinkles in motion) and type III (wrinkles at rest).
Dosage and Frequency
The treatment regimen consisted of four sessions spaced at intervals of 2 to 4 weeks.
The laser parameters were set to a fluence (energy density) of 6.0–13 J/cm². This specific dosing window was designed to stimulate dermal remodeling without causing thermal damage to the epidermis.
Clinical Outcomes and Efficacy
Quantitative Improvement
The primary metric for success was the Glogau photoaging scale.
Assessments conducted three months after the final session revealed that 60% of the subjects improved by at least one grade on the scale. This indicates a measurable transition from "wrinkles at rest" to "wrinkles in motion," or a similar reduction in severity.
Mechanism of Action
The efficacy of this treatment relies on the unique properties of the Q-switched Nd:YAG laser.
Operating at 1064 nm, the laser generates nanosecond-level ultra-short pulses. These pulses create photo-induced stress waves that penetrate the dermis, addressing the structural causes of sagging and wrinkles without ablating the skin surface.
The Safety Profile
Pain Management
A distinct advantage observed in this study was the absence of pain.
Unlike many thermal laser treatments that require topical anesthetics or cooling systems, this protocol was well-tolerated by patients without additional pain management interventions.
Adverse Events
The study reported no adverse side effects.
This suggests that the 1064 nm wavelength, combined with Q-switched delivery, effectively bypasses the melanin-rich epidermis to treat the underlying tissue without causing burns, scarring, or hyperpigmentation.
Understanding the Trade-offs
Sample Size Limitations
It is important to note that this study was conducted on a small sample size (n=10).
While the 60% improvement rate is promising, clinical data from such a small group should be viewed as indicative rather than definitive for the general population.
Severity of Damage
The study specifically targeted mild to moderate cases (Glogau II and III).
There is no evidence in this specific dataset to suggest that this protocol would be equally effective for severe photodamage (Glogau IV), which often involves deep, static wrinkles and significant scarring.
Making the Right Choice for Your Goal
When considering this laser modality for facial rejuvenation, align the treatment with your specific clinical needs:
- If your primary focus is minimal downtime: This protocol provides a painless, risk-free option for reducing wrinkles without the recovery period required by ablative lasers.
- If your primary focus is deep structural repair: You may need to explore more aggressive options, as this laser is optimized for early-stage aging (wrinkles in motion) rather than deep, static folds.
This technology represents a safe, patient-friendly bridge between topical skincare and invasive surgical interventions.
Summary Table:
| Feature | Clinical Study Details |
|---|---|
| Laser Type | 1064 nm Q-switched Nd:YAG |
| Patient Profile | Women with Mild to Moderate Photodamage (Glogau II-III) |
| Treatment Protocol | 4 sessions (intervals of 2-4 weeks) |
| Key Outcome | 60% of subjects improved by ≥1 grade on Glogau scale |
| Safety Profile | Painless, no adverse side effects, zero downtime |
Elevate Your Clinic with BELIS Professional Laser Technology
Maximize patient satisfaction and clinical results with BELIS professional-grade medical aesthetic equipment. As a specialist provider for premium salons and clinics, we offer advanced Nd:YAG and Pico laser systems designed to treat photodamage, pigmentation, and skin aging with maximum safety and zero downtime.
Why partner with BELIS?
- Advanced Laser Precision: Our Nd:YAG systems deliver the exact fluence needed for dermal remodeling without epidermal damage.
- Comprehensive Portfolio: From Diode Hair Removal and CO2 Fractional lasers to HIFU, Microneedle RF, and Body Sculpting (EMSlim, Cryolipolysis).
- Diagnostic Excellence: Integrate our Skin Testers to provide data-driven consultations for your clients.
Ready to upgrade your treatment offerings with the latest in non-invasive facial rejuvenation?
→ Contact BELIS Specialists Today
Related Products
- Q Switch Nd Yag Laser Machine Tattoo Removal Nd Yag Machine
- Pico Picosecond Laser Machine for Tattoo Removal Picosure Pico Laser
- 7D 12D 4D HIFU Machine Device
- Fractional CO2 Laser Machine for Skin Treatment
- Fractional CO2 Laser Machine for Skin Treatment
People Also Ask
- Why is the Q-switched Nd:YAG laser essential for treating PIH? The Gold Standard for Safe Pigment Removal
- How does the 1064nm Nd:YAG laser treat deep hypertrophic scar tissue? Unlock Advanced Dermal Remodeling Solutions
- What are the technical considerations for utilizing a 40 ms pulse width? Optimize Long-pulsed Nd:YAG Laser Safety
- What are Q-switched lasers commonly used for? Remove Tattoos & Pigment with Precision
- How does the Nd:YAG laser work? Unlocking Deep-Tissue Precision for Medical Aesthetics