A typical Super Hair Removal (SHR) machine is defined by a specific optical spectrum of 650-950nm and an energy density ranging from 1-26J/cm². These systems distinguish themselves from traditional lasers through a high pulse repetition rate of 1-10Hz and a broad 15x50mm² spot size, allowing for rapid, "in-motion" treatment delivery.
Core Takeaway Unlike traditional high-energy lasers that rely on single, painful blasts, SHR specifications are optimized for speed and gradual heating. The combination of high frequency (up to 10Hz) and lower fluence (energy density) allows the device to accumulate heat in the follicle effectively while maintaining patient comfort and safety during long operational windows.
Critical Optical Parameters
Wavelength and Filtration
The foundational specification for an SHR machine is a wavelength range of 650-950nm. This spectrum is specifically calibrated to target melanin in the hair follicle while minimizing absorption by water or hemoglobin in the surrounding tissue.
Energy Density (Fluence)
SHR machines operate at an energy density of 1-26J/cm². While this is lower than traditional IPL systems, it is intentional. The lower fluence allows for the rapid repetition of pulses without causing thermal damage to the skin surface.
Pulse Repetition Rate
The defining feature of SHR technology is the Pulse Repetition Rate, which ranges from 1-10Hz. This means the machine can fire up to 10 times per second. This high frequency enables the "sweeping" or "gliding" motion used during treatment, significantly reducing session times compared to stamp-method IPL.
Pulse Duration
The pulse width or duration is adjustable between 1-15ms. This flexibility allows the practitioner to tailor the length of the light exposure based on the patient's hair thickness and skin type.
Operational Hardware Specifications
Spot Size and Coverage
Efficiency is driven by a standard spot size of 15x50mm². This large treatment window allows practitioners to cover extensive body areas, such as backs or legs, rapidly.
Peak Power
To sustain consistent energy delivery across high-repetition pulses, these machines typically utilize an IPL Peak Power of 2400W. This ensures that the first pulse and the tenth pulse in a sequence maintain stable energy levels.
Cooling System
Patient safety and comfort rely on Crystal contact cooling. This feature chills the epidermis immediately upon contact, neutralizing the heat generated by the light energy and preventing surface burns.
Duty Cycle
These machines are engineered for high-volume clinics, capable of continuous work for up to 12 hours. This robust duty cycle ensures the equipment does not overheat or require downtime in the middle of a busy schedule.
Physical and Electrical Constraints
Electrical Requirements
The machine requires a standard voltage input of 100-240VAC at 50/60Hz. However, due to the high peak power, the circuit must handle a 20A maximum load. It is critical to ensure the facility wiring can support this amperage to prevent breaker trips.
Dimensions and Weight
A typical unit has a net weight of 36kg, making it substantial but movable within a room. The physical dimensions are generally 52x48x58cm, allowing it to fit on a sturdy medical cart or countertop.
Understanding the Trade-offs
While the SHR specifications offer speed and comfort, there are technical trade-offs to consider. The lower energy density limit (26J/cm²) means that for extremely stubborn or light-colored hair, the single-pulse impact may be less aggressive than a traditional high-power laser.
Additionally, utilizing the maximum 10Hz repetition rate splits the available power across many pulses. If the power supply (2400W) is not consistent, the energy per pulse may drop slightly at maximum speed. Operators often need to balance the repetition rate against the required energy density to ensure effective follicle destruction.
Making the Right Choice for Your Clinic
When evaluating these specifications against your business needs, consider the following:
- If your primary focus is Patient Throughput: Prioritize the 10Hz repetition rate and the 12-hour continuous work capability to handle back-to-back appointments without device overheating.
- If your primary focus is Treatment Comfort: Focus on the Crystal contact cooling efficiency and the ability to operate at the lower end of the 1-26J/cm² range to provide a pain-free experience.
- If your primary focus is Ease of Integration: specific attention must be paid to the 20A electrical requirement, as standard residential-grade outlets may not suffice without electrical upgrades.
By aligning these technical metrics with your operational goals, you ensure the equipment serves as a reliable engine for your practice rather than a maintenance bottleneck.
Summary Table:
| Parameter | Specification Range | Clinical Benefit |
|---|---|---|
| Wavelength | 650 - 950nm | Optimized melanin targeting with skin safety |
| Pulse Repetition | 1 - 10 Hz (Pulses/sec) | Enables rapid 'in-motion' treatment speed |
| Energy Density | 1 - 26 J/cm² | Effective heat accumulation with high comfort |
| Spot Size | 15 x 50 mm² | Large area coverage for faster sessions |
| Peak Power | 2400W | Stable energy delivery during high-speed use |
| Cooling System | Crystal Contact Cooling | Prevents epidermal burns and minimizes pain |
Elevate Your Clinic with BELIS Professional Aesthetic Solutions
Are you looking to upgrade your practice with high-performance, reliable technology? BELIS specializes in professional-grade medical aesthetic equipment designed exclusively for clinics and premium salons. From the advanced SHR and Diode Laser systems featured in this guide to our cutting-edge Pico lasers, HIFU, and Microneedle RF, we provide the tools you need to deliver superior results.
Why Partner with BELIS?
- Comprehensive Portfolio: Body sculpting (EMSlim, Cryolipolysis), specialized skin care (Hydrafacial, Skin Testers), and hair growth machines.
- Built for Business: Our devices feature robust duty cycles and advanced cooling to handle your busiest days.
- Expert Support: We help you select the right technical specifications to match your patient throughput and treatment goals.
Ready to enhance your treatment efficiency and patient satisfaction? Contact us today to receive a personalized consultation and a competitive quote!
Related Products
- Clinic Use IPL and SHR Hair Removal Machine with Nd Yag Laser Tattoo Removal
- IPL SHR Hair Removal Machine for Permanent Hair Removal
- IPL SHR+Radio frecuency machine
- Diode Laser SHR Trilaser Hair Removal Machine for Clinic Use
- Diode Tri Laser Hair Removal Machine for Clinic Use
People Also Ask
- Where should you not use IPL hair removal? Critical Safety Zones to Avoid
- What is the specific function of Electro-Optical Synergy (ELOS) technology? Unlock Deep Follicle Targeting
- How can incorrect treatment protocols compromise the effectiveness of SHR hair removal? Master Clinical Precision
- What do dermatologists say about IPL? The Truth About Safety and Effectiveness
- Why are cooling sapphire crystals integrated into professional IPL handpieces? Enhance Safety and Fluence.
- What is the clinical significance of choosing different spot sizes for IPL? Master Precision and Depth in Treatments
- What is the purpose of a 1-2 mm IPL distance? Master Non-Contact Photobiomodulation for Better Results
- Does IPL hair removal really work? Unlock Long-Term Hair Reduction with Science