The protocol followed a strict six-session regimen aimed specifically at the pubic area. Treatments were administered at six-week intervals to ensure alignment with the natural hair growth cycle. To ensure consistency, participants were required to shave and clean the area prior to every session and were prohibited from using any other hair removal methods for the duration of the study.
The study relied on a standardized schedule of six treatments spaced six weeks apart, combining rigid patient compliance with individualized energy settings derived from pre-treatment patch tests.
Pre-Treatment Standards and Restrictions
Preparation of the Treatment Area
Consistency was critical to the study's methodology. Before each of the six sessions, the participant's skin was shaved and thoroughly cleaned.
This step removed surface hair to direct the laser energy into the follicle rather than burning the skin surface.
Prohibited Activities
To isolate the effects of the diode laser, the protocol enforced a strict ban on other hair removal techniques.
Throughout the entire course of the study, patients were instructed not to use any other methods of hair removal, such as waxing, plucking, or chemical depilatories.
Technical Specifications and Scheduling
The Treatment Timetable
The study did not follow a general "monthly" cadence often seen in commercial settings.
Participants received a total of 6 treatments. These were scheduled strictly at 6-week intervals.
This specific timing was selected to maximize efficacy by targeting the hair follicles during their active growth phase.
Device Calibration and Settings
While the schedule was fixed, the device settings were not one-size-fits-all.
Parameters such as fluence (J/cm²) and pulse duration (ms) were individually adjusted for each participant.
These adjustments were determined by the skin's reaction during a preliminary patch test, ensuring the highest effective energy level without compromising safety.
Equipment Profile
The study utilized a diode laser operating at a wavelength of 805 nm.
The device featured a specialized 9x9 mm sapphire cooling handle to protect the epidermis.
Pulse duration capabilities ranged from 15 to 400 ms, with energy density capabilities between 10 and 100 J/cm², allowing the customization required by the protocol.
Understanding the Constraints and Criteria
Strict Exclusion Factors
The protocol was designed to minimize variables that could skew results or cause adverse reactions.
Participants were excluded for a wide range of contraindications, including recent sun exposure (suntan), pregnancy, or the use of photosensitizing drugs.
Furthermore, candidates with a history of hypertrophic scars, keloids, or previous laser/IPL treatments in the same area were disqualified to ensure a baseline of untreated skin.
The Necessity of Clinical Judgment
It is important to note that this protocol was not automated.
The reliance on individual patch tests means the success of the protocol depended heavily on the operator's ability to interpret skin reactions.
Replicating this protocol requires more than just the same settings; it requires the same level of real-time clinical assessment.
Applying This Protocol to Clinical Practice
Understanding the specific parameters of this study allows for better replication of its results in a clinical or research setting.
- If your primary focus is efficacy: Adhere strictly to the 6-week interval to catch the hair growth cycle at the optimal moment, rather than the standard monthly approach.
- If your primary focus is safety: Mandate a pre-treatment patch test for every patient to customize fluence and pulse duration rather than using default device settings.
Precision in timing and customization is the defining characteristic of this successful treatment protocol.
Summary Table:
| Protocol Element | Specification Details |
|---|---|
| Total Sessions | 6 Treatments |
| Treatment Interval | 6 Weeks (Aligned with hair growth cycle) |
| Laser Wavelength | 805 nm Diode Laser |
| Cooling Method | 9x9 mm Sapphire Cooling Handle |
| Fluence Range | 10 - 100 J/cm² (Customized via patch test) |
| Pulse Duration | 15 - 400 ms |
| Pre-Treatment | Shaving and thorough cleaning; No waxing/plucking |
Elevate your clinic's hair removal outcomes with BELIS's professional-grade technology. BELIS specializes in premium medical aesthetic equipment, including advanced Diode Laser systems, CO2 Fractional, and Nd:YAG lasers designed for precision and safety. Whether you are looking to upgrade your salon's hair removal capabilities or expand into body sculpting with EMSlim and Cryolipolysis, our systems deliver the clinical results your clients demand. Contact us today to explore our full portfolio and find the perfect solution for your business!
Related Products
- Diode Tri Laser Hair Removal Machine for Clinic Use
- Clinic Diode Laser Hair Removal Machine with SHR and Trilaser Technology
- Trilaser Diode Hair Removal Machine for Beauty Clinic Use
- Diode Laser SHR Trilaser Hair Removal Machine for Clinic Use
- Clinic Use IPL and SHR Hair Removal Machine with Nd Yag Laser Tattoo Removal
People Also Ask
- Why is the Anagen phase crucial for effective diode laser hair removal? Master Timing for Permanent Results
- Why is professional laser hair removal equipment necessary with hormone therapy? Achieve Gender-Affirming Smoothness
- What are the primary safety measures for performing diode laser hair removal on dark skin types? Expert Safety Guide
- How does extending the pulse duration protect dark skin? Master Safe Laser Hair Removal for Fitzpatrick Types IV-VI
- How does a large spot size, such as 20mm, affect laser hair removal? Master Deep Penetration and Clinical Efficiency