A microlens array functions as a sophisticated optical splitter. It leverages physical optics to divide a single high-energy laser beam into a precise matrix of micron-scale spots, commonly arranged in grids of 49 or 81 points. This process ensures energy is distributed evenly across multiple isolated points rather than flooding a single large area with thermal damage.
By fractionating energy into isolated Microscopic Ablation Zones (MAZs), the array stimulates deep dermal repair while preserving bridges of healthy tissue. This "biological reservoir" accelerates healing and maintains the skin’s barrier function.
The Mechanics of Beam Splitting
Optical Redistribution
The fundamental mechanism of the microlens array is optical redistribution. Rather than firing a solid column of light, the lens physically separates the energy into a structured pattern.
This results in a matrix of individual beams, typically creating 49 or 81 distinct points of impact. This division allows the device to deliver high energy without bulk heating the entire treatment area.
Creating Microscopic Ablation Zones (MAZs)
When these fractionated beams hit the skin, they create Microscopic Ablation Zones (MAZs). These are isolated vertical columns of thermal injury.
Because the beams are micron-scale, the ablation is highly controlled. The injury is restricted to these specific zones, leaving the surrounding area untouched.
The Biological Response
The Role of the Biological Reservoir
The most critical aspect of this technology is the intact tissue left between the focal spots. This untreated tissue acts as a "biological reservoir."
Because these areas are healthy and undamaged, they can immediately provide the cells and growth factors needed for repair. This significantly accelerates the process of epidermal regeneration.
Deep Stimulation vs. Surface Integrity
The array allows the laser to penetrate and stimulate the dermis deeply to trigger remodeling. However, because the ablation is fractional, it does not compromise the overall skin barrier function.
This balance allows for the benefits of aggressive deep-tissue treatment with the safety profile of a non-ablative procedure.
Understanding the Trade-offs
Spot Density vs. Intact Tissue
While the primary reference highlights grids of 49 or 81 points, higher spot counts introduce a specific trade-off. Increasing the number of spots increases the total area of ablation.
The Reservoir Limit
As the density of the matrix increases, the volume of the biological reservoir (the intact tissue) decreases. If the matrix becomes too dense, the benefits of rapid regeneration may diminish because there is less healthy tissue available to bridge the gap.
Making the Right Choice for Your Goal
The microlens array is designed to balance efficacy with downtime. How you utilize the spot density affects the clinical outcome.
- If your primary focus is rapid recovery: Prioritize lower-density arrays (fewer spots) to maximize the biological reservoir and speed up epidermal regeneration.
- If your primary focus is deep remodeling: Utilize higher-density arrays (more spots) to increase the volume of Microscopic Ablation Zones (MAZs) for stronger dermal stimulation.
This technology ultimately allows you to decouple deep tissue impact from surface recovery time.
Summary Table:
| Feature | Mechanism | Clinical Benefit |
|---|---|---|
| Beam Splitting | Optical redistribution into 49/81 spots | High energy delivery without bulk thermal damage |
| MAZ Formation | Creation of Microscopic Ablation Zones | Controlled vertical columns of deep tissue injury |
| Biological Reservoir | Preserved healthy tissue bridges | Accelerated healing and maintained barrier function |
| Spot Density | Adjustable matrix configurations | Customizable balance between recovery speed and remodeling intensity |
Elevate Your Clinic’s Precision with BELIS Medical Aesthetics
At BELIS, we specialize in professional-grade medical aesthetic equipment designed exclusively for high-end clinics and premium salons. Our advanced laser systems—including CO2 Fractional, Nd:YAG, Pico, and Diode Hair Removal—utilize cutting-edge microlens array technology to deliver superior patient outcomes with minimal downtime.
Whether you are looking for powerful body sculpting solutions like EMSlim and Cryolipolysis or specialized care devices like Micronedle RF and HIFU, our portfolio is engineered to enhance your service quality and ROI.
Ready to upgrade your practice with industry-leading technology? Contact BELIS today to explore our professional laser systems.
References
- Moshe Lapidoth, Lilian Mayumi Odo. Novel Use of Erbium. DOI: 10.1097/00042728-200808000-00011
This article is also based on technical information from Belislaser Knowledge Base .
Related Products
- Pico Laser Tattoo Removal Machine Picosure Picosecond Laser Machine
- Fractional CO2 Laser Machine for Skin Treatment
- Fractional CO2 Laser Machine for Skin Treatment
- RF Microneedling Machine Micro Needle Radio Frequency Machine
- IPL SHR+Radio frecuency machine
People Also Ask
- What are the unique advantages of Picosecond Laser equipment? Master Stubborn Pigment Removal with Ease
- What does Pico do for skin? Unlock Non-Invasive Skin Rejuvenation
- What is the clinical significance of 9-12 J/cm2 for dark skin? Optimal Safety & Efficacy in Laser Hair Removal
- What are the advantages of using a Picosecond laser over older laser technologies? Superior Speed, Safety, and Efficacy
- What are the technical advantages of picosecond lasers? Why the Photoacoustic Effect is Superior for Tattoo Removal